Regulations

compliance and security

Our guards are designed according to the following norms:

Normative


UNI EN 953

Safety of machinery Guards General requirements for the design and construction of fixed and movable guards.

UNI EN ISO 12100-1/2

Safety of machinery - Basic concepts, general principles for design.

UNI EN 13849-1

Safety of machinery - Safety related parts of control systems - Part 1: General principles for design.

CEI EN 60204-1

Safety of machinery - Electrical equipment of machinery - Part 1: General principles.

UNI EN 1088

Safety of machinery - lnterlocking devices associated with guards. Principles for design and selection.

UNI EN 13857

Safety of machinery - Safety distances to prevent hazard zones being reached by upper and lower limbs.

UNI EN 349

Safety of machinery - Minimum gaps to avoid crushing of parts of the human body.

DIRETTIVA 2006/42/CE

New Machinery Directive.

UNI EN 14119

Safety of machinery - Interlocking devices associated with guards - Principles for design and selection.

Reference table lower limbs


Limitation of free movement under protective structures

The following symbols are used:

  1. reference plane

  2. hip joint

  3. protection structure

piano di riferimento
articolazione dell'anca
struttura di protezione

Irregular openings and accessibility from below: The slot openings > 180 mm, and square or circular > 240 mm do allow access of the entire body.

Height Shelter H Distance S
Case 1 Case 2 Case 3
H ≤ 200 ≥ 340 ≥ 665 ≥ 290
200 < H ≤ 400 ≥ 550 ≥ 765 ≥ 615
400 < H ≤ 600 ≥ 850 ≥ 950 ≥ 800
600 < H ≤ 800 ≥ 950 ≥ 950 ≥ 900
800 < H ≤ 1000 ≥ 1125 ≥ 1195 ≥ 1015

Reference table upper limbs


Reaching upwards

If there is a low risk from hazard zone, then the height of the hazard zone, h, shall be 2 500 mm or more. If there is a high risk from the hazard zone, then:

  • The height of the hazard zone, h, shall be 2 700 mm or more.

  • Other safety measures must be taken

  1. Hazard zone

  2. Reference plane

  3. Protective structure

Accessibilità verso l'alto

Reaching over protective structures

The following symbols can be used:

  1. Height of hazard zone

  2. Height of protective structure

  3. Horizontal safety distance to hazard zone.

Accessibilità al di sopra di strutture di protezione

The table below (high risk situations) does not consider protection structures with height <1000 mm, because they don’t restrict suffi body movement.

Protective structures with height < 1400 mm should not be used without additional security measures.

ln low risk situations are conceivable protective structures of height H 1000 mm. If safety distance is expressed in the table below with a dash, then you must use the distances according to the size of the net, with mesh 32x67 wire 03 or 40x40 wire 03 04, the minimum safety distance is 200 mm.

Height of danger zone A Height of protection structure B
1000 1200 1400 1600 1800 2000 2200 2400 2500 2700
Horizontal distance from the danger zone C
2700 - - - - - - - - - -
2600 900 800 700 600 600 500 400 300 100 -
2400 1100 1000 900 800 700 600 400 300 100 -
2200 1300 1200 1000 900 800 600 400 300 - -
2000 1400 1300 1100 900 800 600 400 - - -
1800 1500 1400 1100 900 800 600 - - - -
1600 1500 1400 1100 900 800 500 - - - -
1400 1500 1400 1100 900 800 - - - - -
1200 1500 1400 1100 900 700 - - - - -
1000 1500 1400 1000 800 - - - - - -
800 1500 1300 900 600 - - - - - -
600 1400 1300 800 - - - - - - -
400 1400 1200 400 - - - - - - -
200 1200 900 - - - - - - - -
0 1100 500 - - - - - - - -

Request information

Fill out the form to request information on the range of products and services offered by Protec.
We will reply as soon as possible.

Request info

©2023 Protec Srl
Social Capital € 10.400,00 i.v.
PI. C.F. e N° Reg. Impr. di Vicenza: 02572680243

REA Code VI: 228079
SDI Code: MJ1OYNU for the companies SICURA S.p.A., Evimed S.r.l., Protec S.r.l.