Our guards are designed according to the following norms:
Normative
UNI EN 953
Safety of machinery Guards General requirements for the design and construction of fixed and movable guards.
UNI EN ISO 12100-1/2
Safety of machinery - Basic concepts, general principles for design.
UNI EN 13849-1
Safety of machinery - Safety related parts of control systems - Part 1: General principles for design.
CEI EN 60204-1
Safety of machinery - Electrical equipment of machinery - Part 1: General principles.
UNI EN 1088
Safety of machinery - lnterlocking devices associated with guards. Principles for design and selection.
UNI EN 13857
Safety of machinery - Safety distances to prevent hazard zones being reached by upper and lower limbs.
UNI EN 349
Safety of machinery - Minimum gaps to avoid crushing of parts of the human body.
DIRETTIVA 2006/42/CE
New Machinery Directive.
UNI EN 14119
Safety of machinery - Interlocking devices associated with guards - Principles for design and selection.
Reference table lower limbs
Limitation of free movement under protective structures
The following symbols are used:
-
reference plane
-
hip joint
-
protection structure
Irregular openings and accessibility from below: The slot openings > 180 mm, and square or circular > 240 mm do allow access of the entire body.
Height Shelter H | Distance S | ||
Case 1 | Case 2 | Case 3 | |
H ≤ 200 | ≥ 340 | ≥ 665 | ≥ 290 |
200 < H ≤ 400 | ≥ 550 | ≥ 765 | ≥ 615 |
400 < H ≤ 600 | ≥ 850 | ≥ 950 | ≥ 800 |
600 < H ≤ 800 | ≥ 950 | ≥ 950 | ≥ 900 |
800 < H ≤ 1000 | ≥ 1125 | ≥ 1195 | ≥ 1015 |
Reference table upper limbs
Reaching upwards
If there is a low risk from hazard zone, then the height of the hazard zone, h, shall be 2 500 mm or more. If there is a high risk from the hazard zone, then:
-
The height of the hazard zone, h, shall be 2 700 mm or more.
-
Other safety measures must be taken
-
Hazard zone
-
Reference plane
-
Protective structure
Reaching over protective structures
The following symbols can be used:
-
Height of hazard zone
-
Height of protective structure
-
Horizontal safety distance to hazard zone.
The table below (high risk situations) does not consider protection structures with height <1000 mm, because they don’t restrict suffi body movement.
Protective structures with height < 1400 mm should not be used without additional security measures.
ln low risk situations are conceivable protective structures of height H 1000 mm. If safety distance is expressed in the table below with a dash, then you must use the distances according to the size of the net, with mesh 32x67 wire 03 or 40x40 wire 03 04, the minimum safety distance is 200 mm.
Height of danger zone A | Height of protection structure B | |||||||||
1000 | 1200 | 1400 | 1600 | 1800 | 2000 | 2200 | 2400 | 2500 | 2700 | |
Horizontal distance from the danger zone C | ||||||||||
2700 | - | - | - | - | - | - | - | - | - | - |
2600 | 900 | 800 | 700 | 600 | 600 | 500 | 400 | 300 | 100 | - |
2400 | 1100 | 1000 | 900 | 800 | 700 | 600 | 400 | 300 | 100 | - |
2200 | 1300 | 1200 | 1000 | 900 | 800 | 600 | 400 | 300 | - | - |
2000 | 1400 | 1300 | 1100 | 900 | 800 | 600 | 400 | - | - | - |
1800 | 1500 | 1400 | 1100 | 900 | 800 | 600 | - | - | - | - |
1600 | 1500 | 1400 | 1100 | 900 | 800 | 500 | - | - | - | - |
1400 | 1500 | 1400 | 1100 | 900 | 800 | - | - | - | - | - |
1200 | 1500 | 1400 | 1100 | 900 | 700 | - | - | - | - | - |
1000 | 1500 | 1400 | 1000 | 800 | - | - | - | - | - | - |
800 | 1500 | 1300 | 900 | 600 | - | - | - | - | - | - |
600 | 1400 | 1300 | 800 | - | - | - | - | - | - | - |
400 | 1400 | 1200 | 400 | - | - | - | - | - | - | - |
200 | 1200 | 900 | - | - | - | - | - | - | - | - |
0 | 1100 | 500 | - | - | - | - | - | - | - | - |